Section 3: Connecting services to the fabric

The blueprint now includes the modeled rack and network segments. In this section, you will model an analytics server and attach it to the two virtual networks. You will configure external BGP peering in the next section.

Adding a server (generic system)

Servers and external devices connected to the fabric are modeled as generic systems. Modeling them records their connections alongside the network design and allows Data Center Director to generate the appropriate switch port configurations.

In this lab, the new rack and analytics server are modeled in the blueprint; no additional physical devices are assigned.

  • Navigate to Staged[Physical > Topology].

  • Locate the new rack you added in the previous section.

  • Click on one of the new leaf switches in that rack. Remember that this rack is part of the configuration now, even though the exercise does not call for us to assign physical devices.

Selecting a leaf switch in the new rack
  • Click the box to the left of the device name.

  • Select Add internal/external generic system.

Add generic system menu option

Enter the following values:

Parameter Value

Generic Type

Internal

Name

analytics-server-1

Hostname

analytics-server-1

Logical Device

AOS-2x10-1

Tag

server

What is AOS-2x10-1? It is a logical device that describes the server’s connectivity characteristics. In this case, it defines a server with two 10 Gbps ports, helping Data Center Director configure the switch ports facing the server.

Generic system details form
  • Click Next.

Model a redundant server connection to both leaf switches in the rack — one link to each. In a deployed fabric, this design can maintain connectivity if one leaf fails, provided the server, links, and LAG are configured and operational.

Action Detail

Leaf 1

Select an available port (e.g. port 4), set speed to 10 Gbps, and click Add Link.

Leaf 2

Select a corresponding port, set speed to 10 Gbps, and click Add Link.

  • Set Deploy mode to Deploy.

  • Select Create LAG? and set Lag mode to LACP (Active).

  • Add a link tag - server

Completed server link configuration

What is LACP? LACP (Link Aggregation Control Protocol) negotiates a link aggregation group, combining physical links into a logical connection. Setting it to active means the leaf switches initiate LACP negotiation. With a compatible server configuration and operational links, ESI-LAG can provide a redundant connection across both leaf switches.

  • Review both links, then click Create.

Applying connectivity templates

A connectivity template defines which virtual networks a server’s switch ports should carry. Rather than configuring individual VLANs on individual ports, you select a template that represents the desired connectivity outcome, then apply it to the interfaces you want.

When you created the analytics-web and analytics-db virtual networks in the previous section, a connectivity template for each VN was created. Remember when you clicked 'Tagged' on the form?

Think of connectivity templates as expressing what you want to achieve — "this server connects to these networks" — rather than how to configure it, which Data Center Director works out automatically.

  • Navigate to Staged[Connectivity Templates].

  • Confirm you can see Tagged VxLAN 'analytics-web' and Tagged VxLAN 'analytics-db' in the list.

If you do not see these templates, navigate to Virtual > Virtual Networks, select each virtual network, and use the export icon to generate them. Call out to your instructor if you are unsure.

Connectivity templates list

You can click on a template to see how it is built before applying it.

Connectivity template detail view
  • Return to the Connectivity Templates list.

  • Select BOTH new templates and click the Assign icon.

  • In the row for the aggregate interface connected to analytics-server-1, select the checkbox for each template. Do not select unrelated interfaces.

  • Click the Assign icon (the one above the table).

Assigning connectivity templates to server interfaces

The screenshot doesn’t show the server tag, you created. Notice how it makes it easy to find the server in the Assign table. Tags are your friends.

The two templates add the tagged virtual networks to the modeled server connection. The LAG was defined earlier when you created the server links. Data Center Director generates the corresponding switch configuration from the blueprint.

  • Navigate to Staged[Physical > Topology].

  • Select a leaf switch and check the Incremental Configuration tab to see the configuration that has been generated.

Incremental config showing the server port configuration changes
  • Click the Uncommitted tab, enter a commit message such as Connected analytics server to virtual networks, and click Commit.