Section 2: Expanding the fabric
In our real-world scenario, your organization has approved a new Big Data Analytics service. You need to expand the data center to support it. You will define new capacity, add a dedicated routing domain to isolate the service, and configure two new virtual network overlays for a web tier and a database tier.
|
Your scenario: Add a new rack, create a dedicated routing zone (VRF) for the analytics workload, and build virtual networks for a web tier and a database tier — all through the system’s UI, without touching a device command line. |
Adding a new rack
In a traditional environment, adding a rack means planning IP addressing, ASN assignments, underlay BGP, and overlay EVPN — and then manually configuring each new switch. Data Center Director uses the fabric model to generate configurations for the new rack and affected devices.
|
As you perform this step, consider this: How long would it take your team to prepare and install a pair of switches from scratch, including IP planning, ASN allocation, BGP and EVPN configuration, and testing? |
-
Navigate to the Staged[Physical > Racks] tab.
-
Click the Add Racks button (+).
-
From the Rack Type drop-down, select evpn-esi.
|
What is evpn-esi? EVPN-ESI is the standard redundant rack design for modern data centers. It uses two leaf switches working in tandem — EVPN (Ethernet VPN) carries the overlay networking across the fabric, and ESI-LAG (Ethernet Segment Identifier Link Aggregation) allows servers to connect to both leaf switches simultaneously for redundancy. If one leaf fails, the other maintains connectivity for the server. This design is a common "best practice" for modern data centers. |
-
Leave the count at 1.
-
Click Add.
|
You have staged the addition of a new rack without having the hardware present. Data Center Director can model the expansion before the switches arrive. Once the switches are installed, cabled, and onboarded, their configurations can be deployed. |
Assigning device profiles
A device profile describes characteristics such as port layout, speeds, and operating system for a device. Data Center Director includes predefined profiles for a range of models and vendors. In this lab, you will assign an interface map associated with the appropriate device profile to each new leaf switch.
-
Navigate to Staged[Physical > Topology].
-
In the right-hand panel, select Build, then click the Device Profiles icon.
The new rack devices appear in yellow to indicate uncommitted changes. The red indicator in the Device Profiles panel shows that assignments are needed for the new leaf switches.
-
Select the red indicator for slicer-7x10-1, then click the edit icon to open the interface map assignment view.
-
Assign the Juniper_vEX__slicer-7x10-1 interface map to each new leaf switch.
-
Click Update Assignments. There are no additional devices to deploy into this blueprint in today’s lab, so the new switches remain modeled rather than deployed.
Reviewing the generated configuration
Now that the profiles are assigned, inspect the configuration generated for the staged design before committing it.
-
Navigate to Staged[Physical > Topology] tab.
-
Click on one of your new leaf switches that were just defined.
-
Click the Rendered Config tab, as shown and review the contents.
Data Center Director uses the blueprint and resource pools to generate the configuration for the new rack and affected existing devices. Select other devices and review their incremental configurations to see the changes proposed for each one.
|
The proposed changes include updates to the spine switches so they can peer with the new leaves. Data Center Director identifies those changes from the blueprint model. |
Your first commit
A commit in Data Center Director applies the staged blueprint changes. The system generates configuration changes for affected devices and deploys them to available devices as appropriate. The new rack remains modeled until its switches are available and onboarded. The commit is recorded in the blueprint history, which you will use later to review and roll back changes.
A meaningful commit message helps you find the right point in the change history if you need to roll the network back.
-
Navigate to the Uncommitted tab.
-
Enter a commit message such as, Prestaged new analytics rack.
-
Click Commit.
Creating a routing zone (VRF)
A routing zone consists of a VRF and policies that enable multitenancy in the data center fabric. The new Analytics workload needs its own routing zone to help isolate its traffic from other services.
In a traditional environment, creating a VRF means configuring route distinguishers, route targets, and import/export policies on every relevant switch by hand. Data Center Director does this via the selection of one field.
-
Navigate to Staged[Virtual > Routing Zones].
-
Click Create Routing Zone.
-
Enter Analytics as the name.
|
That is the only required field. The system determines the route distinguisher, route targets, and default routing policies automatically. They are derived from the resource pools that are set up early in the Design phase. |
-
Set to IPv4 Only (default).
-
Scoll down, if necessary and set the Routing Policy to Default_immutable.
-
Leave all other fields at their defaults.
-
Click Create.
Check the incremental configuration
-
Navigate to Staged[Physical > Topology] tab and select any leaf switch.
-
Click the Incremental Configuration tab.
The incremental configuration is empty right now, and this is what we expect. A VRF is only pushed to a switch when a virtual network within the VRF is assigned to the particular switch. Creating the routing zone simply registers the intent and the configuration follows when something actually requires that entity.
-
Click the Uncommitted tab, enter a commit message such as Added Analytics routing zone, and click Commit.
Creating virtual networks
The analytics service needs two separate network segments. The web tier needs extra security because its traffic would be inspected by an external firewall. The database tier is internal-only and can be routed directly within the fabric. These two requirements lead to two different virtual network designs.
Web tier (Layer 2 only)
-
Navigate to Staged[Virtual > Virtual Networks].
-
Click Create Virtual Network.
Enter the following values:
| Parameter | Value |
|---|---|
Type |
VXLAN |
Name |
analytics-web |
Routing Zone |
Analytics |
Switching Zone |
Default switching zone |
IPv4 Connectivity |
Disabled (change from default setting) |
IPv6 Connectivity |
Disabled |
|
Why disable IPv4 Connectivity? Disabling it creates a Layer 2-only network, often called a bridged overlay. VXLAN extends the bridge domain across the fabric without an anycast gateway in the virtual network. In this scenario, an external firewall provides the gateway and can inspect traffic routed through it. |
-
For the Create Connectivity Templates for field, select Tagged.
|
Tagged means the VLAN identifier is preserved on the wire. The switch port carries traffic with an 802.1Q tag, allowing multiple networks to share the same physical interface (trunking). This is a standard practice for server ports that need to reach more than one network. |
-
Scroll down to Assigned To and select all racks.
|
Assigning the network to all racks makes it available across the fabric. Servers still need the appropriate connectivity before they can use it. |
-
Click Create.
Database tier (Layer 3)
-
Now, click Create Virtual Network for the second overlay network.
Enter the following values:
| Parameter | Value |
|---|---|
Type |
VXLAN |
Name |
analytics-db |
Routing Zone |
Analytics |
Switching Zone |
Default switching zone |
IPv4 Connectivity |
Enabled |
IPv4 Subnet |
10.1.2.0/24 |
Virtual Gateway IP |
10.1.2.1 |
IPv6 Connectivity |
Disabled |
|
Why enable IPv4 Connectivity here? The database tier is internal — it does not need to pass through an external firewall. Enabling IPv4 Connectivity places the Anycast gateway (10.1.2.1) directly on the leaf switches, so database traffic routes efficiently within the fabric without leaving it. |
-
In Create Connectivity Templates for, select Tagged.
-
In Assigned To, select all racks.
-
Click Create.
Assigning resource pools
After creating the virtual networks, a red indicator identifies that the Analytics routing zone now needs loopback IP addresses. These are allocated from IP address pools that were configured early in the Design phase (not covered in this exercise,so we built them for you).
-
Click the red indicator and assign any available pool from the list.
Data Center Director allocates IP addresses from the selected pool to the switches as needed.
|
You can create IP pools under Resources or assign loopback IP addresses manually. Using a pool lets Data Center Director allocate addresses as needed. |
Verify the incremental configuration
-
Navigate to Staged[Physical > Topology]
-
Select a leaf switch and click the Incremental Configuration tab again.
Compare this to the empty tab you saw earlier. The system has now generated VXLAN VNI mappings, VRF configuration, EVPN route-target policies, and interface assignments. This is all because you assigned two virtual networks to every rack. This is the configuration it will push to this switch when you commit.
-
Click the Uncommitted tab, enter a commit message such as Added Analytics virtual networks, and click Commit.
Continue to Milestone 2.